A dedicated touchscreen for your solar, grid, home and battery information. Connect directly to supported equipment, or bring it all together with Home Assistant.
Illustrated panel with example data. Firmware screenshots and product photography are being prepared. Battery readings require a supported battery installation.
Solar production
What your panels produce
Grid import & export
Where your power goes
Home consumption
What your home uses
Battery information
Where installed & supported
How it works
Your system. Two ways to connect.
Start with live energy information. Add Home Assistant for history, summaries and configured forecasts.
01Direct connection
Standalone
The display connects directly to supported equipment over your local network. No Home Assistant installation is needed.
Energy equipment→Local network→Clevr display
Live solar, grid import/export and load power
Battery readings where installed and supported
Equipment and connection status
Current standalone firmware does not provide the Home Assistant history or forecast features.
02Connected experience
With Home Assistant
Home Assistant, a home automation platform, gathers your equipment readings and supplies them to the display.
No implementation is listed for this combination. This is not a confirmed compatible setup.
Implementation status is not a firmware release guarantee. Available identifies an implementation described in the supplied project notes; release versions and physical test details still need owner review. Deye is experimental and has not been tested on real hardware. High-voltage Deye families and excluded register maps are unsupported by this package. A 5-inch Deye standalone release is not available.
Choose your panel
Two sizes. One clear view.
Use firmware that matches the exact panel model. A package for one panel is not interchangeable with the other.
4-inch480 × 480
4-inch square
ESP32 touchscreen
A compact, square view of your energy flow.
Guition 4848S040480 × 480
Victron standalone, Victron with Home Assistant, and experimental Deye standalone implementations.
The guide site currently shows a preparation page. Version-specific installation steps are pending.
ExperimentalFull guide being prepared
Deye setup
Current standalone development targets the 4-inch panel and the listed low-voltage LP1 / LP3 families. Confirm the installed logger or gateway; the inverter name alone does not establish Solarman V5 support.
Connection details you will need
Logger IP: the logger’s address on your local network
Logger serial: the identifier of the installed logger, not necessarily the inverter serial
Transport and port: the connection method and network endpoint required by your logger
Inverter address: the device address used by the matching profile
Use verified values from your equipment and matching release guide. Defaults are not confirmed yet.
Experimental: simulated tests only. The guide site currently shows a preparation page.
What standalone first-time setup looks like
Welcome → inverter selection → Wi-Fi → equipment/logger IP → connection test → save and open dashboard. Choose your Wi-Fi network and enter the password on the panel. Recovery instructions will be documented separately.
Downloads
Match the package to your panel.
Downloads will be published with a version, archive contents and matching instructions. No firmware files have been supplied yet.
ExperimentalDownload pending
Victron + Deye standalone development package
Version
Not supplied
Panel
Guition 4848S040 · 4-inch
Equipment
Victron; experimental Deye LP1 / LP3
Mode
Standalone
Contains
Archive contents and format require confirmation. No flashable binary has been supplied.
A source archive contains project files; it cannot be flashed directly. Flashable binaries will be identified explicitly when available.
Your next step
Find the right setup for your system.
Choose your equipment, operating mode and panel to see what is currently implemented.
Support
A few useful answers.
Do I need Home Assistant?
No, if your equipment and panel support standalone mode. Home Assistant is needed for the richer history, daily summary and configured forecast experience. Check the compatibility table before choosing.
Why is my equipment not listed?
Only the implementations described in the project notes are listed. A reserved manufacturer subdomain does not mean an integration is available. Unlisted equipment needs confirmation before use.
What should I check if the panel cannot connect?
Confirm the selected equipment profile, Wi-Fi connection, equipment or logger IP address, and access across your local network. For Deye, also verify the logger compatibility, serial, transport, port and inverter address against the matching release instructions. Do not guess missing connection values.
Why are battery readings or forecasts missing?
Battery readings require an installed, supported battery and equipment that provides the data. Forecasts require Home Assistant mode plus a configured forecast integration and sensors. These are conditional features.
Where are the firmware files and full installation instructions?
They are being prepared. No downloadable release or firmware version has been supplied for publication yet. The package cards show exactly what still needs confirmation.